Univention Bugzilla – Bug 30402
Blank screen when multiple display are configured but not attached
Last modified: 2014-06-12 09:19:53 CEST
I have more than one display configured with a UCC hadware policy. The second display is not connected during boot. After leaving the bootsplash the screen goes blank. If the display is connected at a later point, the screen looks as expected. Testdevice was an Acer Travelmate 8371.
Reproducable with a shuttle barebone (Intel Atom + Nvidia), if the behaviour of the second screen is defined in UDM systems with only one monitor connected are unusable.
fixed in /usr/sbin/univention-ucc-setup-multimonitor. (1) disable all disconnected displays (2) do nothing if primary or secondary display name is not set, or if both are equal
Ok: When configuring a dual monitor policy both screens are activated. After pulling the cable of the second monitor only the primary one is active.
UCC 2.0 has been released: http://docs.univention.de/release-notes-ucc-2.0.html If this error occurs again, please use "Clone This Bug".