Bug 32471 - AppCenter-ify software page of System setup
AppCenter-ify software page of System setup
Status: CLOSED FIXED
Product: UCS
Classification: Unclassified
Component: UMC - Basic settings
UCS 3.2
Other Linux
: P5 normal (vote)
: UCS 3.2
Assigned To: Dirk Wiesenthal
Stefan Gohmann
: interim-2
Depends on:
Blocks:
  Show dependency treegraph
 
Reported: 2013-09-03 15:49 CEST by Dirk Wiesenthal
Modified: 2013-11-19 06:41 CET (History)
1 user (show)

See Also:
What kind of report is it?: ---
What type of bug is this?: ---
Who will be affected by this bug?: ---
How will those affected feel about the bug?: ---
User Pain:
Enterprise Customer affected?:
School Customer affected?:
ISV affected?:
Waiting Support:
Flags outvoted (downgraded) after PO Review:
Ticket number:
Bug group (optional):
Max CVSS v3 score:


Attachments
Use the AppCenter as SoftwarePage (20.81 KB, patch)
2013-09-03 16:01 CEST, Dirk Wiesenthal
Details | Diff

Note You need to log in before you can comment on or make changes to this bug.
Description Dirk Wiesenthal univentionstaff 2013-09-03 15:49:26 CEST
As software components are moved to the App Center (Bug#32301) the software page in system setup is outdated.

Two possibilities:
1) Integrate a slightly modified version of the App Center in system setup
2) Remove the software page completely

1)
Pro: No loss of functionality

2)
Pro: Easy to do
Contra: At least the appliance mode needs something like the software page
Comment 1 Stefan Gohmann univentionstaff 2013-09-03 15:53:42 CEST
For UCS 3.2 the software component page should be available in the appliance mode only.
Comment 2 Dirk Wiesenthal univentionstaff 2013-09-03 16:01:50 CEST
Created attachment 5406 [details]
Use the AppCenter as SoftwarePage

Using the App Center in System setup. Backwards compatible with old profile files. Sends notifications. Should work offline (not yet tested). Some minor issues with ProgressBar reaching 100% too soon.
Comment 3 Stefan Gohmann univentionstaff 2013-09-09 16:54:10 CEST
(In reply to Stefan Gohmann from comment #1)
> For UCS 3.2 the software component page should be available in the appliance
> mode only.
Comment 4 Dirk Wiesenthal univentionstaff 2013-09-09 18:21:54 CEST
Fixed in
  univention-system-setup 7.0.39-1.512.201309091726

I have also removed the high fraction for 10software when not in wizard_mode. Otherwise the whole script finishes after 45% or something.
Comment 5 Lukas Walter univentionstaff 2013-09-19 14:05:15 CEST
fail: The software page is missing in appliance mode
ok: changelog 3.2
Comment 6 Dirk Wiesenthal univentionstaff 2013-09-20 11:08:22 CEST
Works in my tests. Could you recheck?
Comment 7 Lukas Walter univentionstaff 2013-09-20 12:20:19 CEST
(In reply to Dirk Wiesenthal from comment #6)
> Works in my tests. Could you recheck?

After booting into the appliance mode, I had to stop a not reacting script, which lead to a not working software page hanging in an infinite loading loop.
Comment 8 Dirk Wiesenthal univentionstaff 2013-09-20 17:39:35 CEST
Seems to be a bug in some frontend function that was present while the UCS 3.2 test images were built. Works after apt-get dist-upgrade
Comment 9 Stefan Gohmann univentionstaff 2013-09-26 11:27:49 CEST
OK, it worked like expected for the appliance mode and for the normal mode. Changelog OK.
Comment 10 Stefan Gohmann univentionstaff 2013-11-19 06:41:28 CET
UCS 3.2 has been released:
 http://docs.univention.de/release-notes-3.2-en.html
 http://docs.univention.de/release-notes-3.2-de.html

If this error occurs again, please use "Clone This Bug".