Univention Bugzilla – Bug 36880
Appliance wizard hangs due to JavaScript error for multiple network interfaces
Last modified: 2014-11-26 06:55:34 CET
Created attachment 6433 [details] Screenshot See screeshot for JS exact error, reproducible with two network interfaces where one (in this case eth1) is not configured via UCR.
Due to this bug, it is currently not possible to install a system from DVD with more than one network interface.
Workaround: * Strg + Q to quit the appliance mode * for all unconfigured network interfaces: ucr set interfaces/eth1/type=dhcp * /etc/init.d/univention-system-setup-boot start
Fixed. Package is building. Changelog entry not necessary. univention-system-setup (8.1.63-1): * Bug #36880: fix exception due to undefined reference
I was able to reproduce it. With the new DVD the bug has been fixed. I see ascrollbar if I use four network cards: Bug 36884 - Appliance wizard shows a scrollbar when using four network cards
UCS 4.0-0 has been released: http://docs.univention.de/release-notes-4.0-0-en.html http://docs.univention.de/release-notes-4.0-0-de.html If this error occurs again, please use "Clone This Bug".