Univention Bugzilla – Bug 21712
Traceback beim beenden eine Maschine
Last modified: 2011-04-04 15:48:19 CEST
Die Ausführung des Kommandos 'uvmm/domain/stop' ist fehlgeschlagen: Traceback (most recent call last): File "/usr/lib/python2.4/site-packages/univention/management/console/handlers/__init__.py", line 160, in execute func( object ) File "/usr/lib/python2.4/site-packages/univention/management/console/handlers/uvmm/__init__.py", line 1095, in uvmm_domain_state resp = self.uvmm.domain_set_state( object.options[ 'node' ], object.options[ 'domain' ], object.options[ 'state' ] ) File "/usr/lib/python2.4/site-packages/univention/management/console/handlers/uvmm/uvmmd.py", line 362, in domain_set_state domain_info = self.get_domain_info( node_uri, domain_name ) File "/usr/lib/python2.4/site-packages/univention/management/console/handlers/uvmm/uvmmd.py", line 261, in get_domain_info node_info, domain_info = self.get_domain_info_ext( node_uri, domain_name ) File "/usr/lib/python2.4/site-packages/univention/management/console/handlers/uvmm/uvmmd.py", line 253, in get_domain_info_ext for domain_info in node_info.domains: AttributeError: 'NoneType' object has no attribute 'domains'
War das Xen oder KVM? Kannst du noch die Logs vom UVMMd anhängen?
Created attachment 3085 [details] xen.logs.tar.bz2 Das war Xen
fixed \item Diverse Fehlerzustände im UVMM UMC Modul werden nun besser abgefangen (\ucsBug{21701}, \ucsBug{21712}).
Problem trat in der QA so nicht mehr auf. Changelogeintrag vorhanden - verified
UCS 2.4-2 wurde veröffentlicht. Sollte der hier beschriebene Bug mit einer neueren Version von UCS erneut auftreten, so sollte der Bug dupliziert werden: "Clone This Bug".