Univention Bugzilla – Bug 39719
S4 Connector join script failed on DC Backup
Last modified: 2015-11-17 12:12:29 CET
The join of a DC Backup failed: -------------------------------------------------------------------------------- Object created: cn=mswmi,cn=ldapschema,cn=univention,dc=deadlock44,dc=intranet Object created: cn=container/msgpo,cn=udm_module,cn=univention,dc=deadlock44,dc=intranet Waiting for activation of the extension object msgpo:....................................................ERROR: Master did not mark the extension object active within 180 seconds. ERROR ucs_registerLDAPExtension: registraton of /usr/share/univention-s4-connector/ldap/msgpo.schema failed. -------------------------------------------------------------------------------- Afterwards, univention-run-join-scripts succeeded. I thing the 180 seconds are not enough.
As discussed, we should decrease the graceful restart timeouts of the slapd init script.
Ok I adjusted the graceful restart plan to HUP/10/TERM/5/KILL/1. Joining a DC Backup and a DC Slave was successful. Changelog adjusted.
* Tests: OK * Changelog : OK Waiting for ucs-test ...
(In reply to Stefan Gohmann from comment #3) > Waiting for ucs-test ... ucs-test were successful.
UCS 4.1 has been released: https://docs.software-univention.de/release-notes-4.1-0-en.html https://docs.software-univention.de/release-notes-4.1-0-de.html If this error occurs again, please use "Clone This Bug".