Univention Bugzilla – Bug 46312
Increase univention-directory-notifier sv start timeout to 30 seconds
Last modified: 2018-02-28 13:52:59 CET
On some systems the default timeout of 7 seconds for the sv start command is not enough. I had to increase the timeout to 30 seconds: sv -w 30 start univention-directory-notifier In the medium term, we will replace the runit scripts with systemd scripts. Unfortunately, we need a fix for UCS 4.2 now.
[4.2-3 658fdbfafa] Bug #46321: increase runsv timeout to 30 seconds [4.2-3 5c8a764fe0] Bug #46312: fix bugnumber [4.2-3 d2eae2464f] Bug #46312: YAML [4.3-0 1e1402bc5f] Bug #46321: increase runsv timeout to 30 seconds [4.3-0 f56356efcf] Bug #46312: fix bugnumber [4.3-0 ffc2257e38] Bug #46310, #46311, #46312, #46313: release changelog
Tests: OK YAML: OK Code review: OK UCS 4.3 merge: OK
<http://errata.software-univention.de/ucs/4.2/308.html>