+++ This bug was initially created as a clone of Bug #50620 +++ Situation: Internal DNS does not resolve external addresses. Access to internet only works through http-proxy. Running the diagnostic checks fails: univention-run-diagnostic-checks --username Administrator --bindpwdfile <(echo -n univention) -t 11_nameserver timeout resolving 'www.univention.de' with NS X.X.X.X univention-run-diagnostic-checks --username Administrator --bindpwdfile <(echo -n univention) -t 12_proxy Failed writing body (0 != 8088) (code=23) univention-run-diagnostic-checks --username Administrator --bindpwdfile <(echo -n univention) -t 23_check_update_sites {updates,appcenter}.software-univention.de are not resolvable The PROXY server does that, the host itself does not need to be able to resolve the host
Package: univention-management-console-module-diagnostic Version: 5.0.1-52A~4.4.0.202107141003 Branch: ucs_4.4-0 Scope: errata4.4-8 4.4-8: 6972d32a0f6c493423d003f3c575df09f85464c9 (yaml) d84e1689f2063430237a353b5eb72c1ebeb6fc7e (changes) The System Diagnostic check no longer shows false positives when a http-proxy is set.
OK: fix OK: code review OK: YAML (adjusted to the text from UCS 5): 44a686c1f685 | YAML Bug #53575
<https://errata.software-univention.de/#/?erratum=4.4x1012>