Univention Bugzilla – Bug 55160
Control elements in the computer list flicker constantly
Last modified: 2023-04-21 10:25:01 CEST
UCS@School 5.0 V3 Computerraum-Modul If at least 1 computer in the computer room is switched on (i.e. accessible to Veyon), the computer list seems to be constantly updated, in such a way that many control elements "flicker" in one tour. The following things happen every 2 seconds: - The checkboxes of the selected computers reset briefly to "not selected" and then immediately to "selected" again - The background color "pulses" briefly in a darker shade of gray - If you scroll further down the computer list with the scroll bar, the computer list is not rendered at all and remains completely empty The customer has a computerroom with 118 computers in it. This problem occurs quite often at the school, because there is a "room" at each school with all computers of the school, which is usually used to start or shut down all computers in the school.
Update from the customer from Bug 55162 There seems to be a connection between the occurrence of Veyon tracebacks in management-console-module-computerroom.log and the operating problems in the UMC. Because without tracebacks, the flickering (Bug 55160) also stops and, in particular, all computers can actually be checked via the checkbox! (Bug 55162)
This also seems to have been solved by the new Veyon app version 4.7.4.14-0!
Asked for clarification if the issue still persists or if Veyon Proxy version 4.7.4.14 solved it.