Reported: 2024-05-27 10:41 CEST by Mirac Erdemiroglu
Modified: 2024-09-20 12:39 CEST (History)
2 users (show)

See Also:
What kind of report is it?: Bug Report
What type of bug is this?: 5: Major Usability: Impairs usability in key scenarios
Who will be affected by this bug?: 1: Will affect a very few installed domains
How will those affected feel about the bug?: 5: Blocking further progress on the daily work
User Pain: 0.143
Enterprise Customer affected?:
School Customer affected?: Yes
ISV affected?:
Waiting Support:
Flags outvoted (downgraded) after PO Review: Yes
Ticket number: 2024041721000145
Bug group (optional):
Customer ID:
Max CVSS v3 score:


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Mirac Erdemiroglu univentionstaff 2024-05-27 10:41:17 CEST
UCS: 5.0-6 errata904
Installed: cups=2.2.1 dhcp-server=12.0 prometheus-node-exporter=2.0.1 radius=5.0 samba4=4.16 self-service=5.0 squid=3.5 ucsschool=5.0 v4 4.4/ucsschool-veyon-proxy=4.7.4.14-0
Upgradable:


Due to a communication problem with Veyon, the Exam mode may be canceled or terminated.
This should also be indicated in the UMC exactly why the exam mode is terminated instead of simply terminating it because a problem has arisen.


15.05.24 14:15:19.761  MODULE      ( INFO    ) : E-R300-01: updating information.
15.05.24 14:15:19.773  MODULE      ( WARN    ) : Veyon error on E-R300-01: Invalid connection
15.05.24 14:15:19.775  MODULE      ( WARN    ) : E-R300-01: Updating information was not successful.
15.05.24 14:15:19.868  MODULE      ( INFO    ) : E-R300-02: updating information.
15.05.24 14:15:19.876  MODULE      ( WARN    ) : Veyon error on E-R300-02: Invalid connection
15.05.24 14:15:19.878  MODULE      ( WARN    ) : E-R300-02: Updating information was not successful.
15.05.24 14:15:19.948  MODULE      ( INFO    ) : E-R300-03: updating information.
15.05.24 14:15:19.960  MODULE      ( WARN    ) : Veyon error on E-R300-03: Invalid connection
15.05.24 14:15:19.962  MODULE      ( WARN    ) : E-R300-03: Updating information was not successful.
15.05.24 14:15:19.977  MODULE      ( INFO    ) : E-R300-04: updating information.
15.05.24 14:15:19.999  MODULE      ( INFO    ) : E-R300-05: updating information.
15.05.24 14:15:20.006  MODULE      ( WARN    ) : Veyon error on E-R300-05: Invalid connection
15.05.24 14:15:20.008  MODULE      ( WARN    ) : E-R300-05: Updating information was not successful.
15.05.24 14:15:20.040  MODULE      ( INFO    ) : E-R300-09: updating information.
15.05.24 14:15:20.050  MODULE      ( WARN    ) : Veyon error on E-R300-09: Invalid connection
15.05.24 14:15:20.053  MODULE      ( WARN    ) : E-R300-09: Updating information was not successful.
15.05.24 14:15:20.082  MODULE      ( INFO    ) : E-R300-11: updating information.
15.05.24 14:15:20.091  MODULE      ( WARN    ) : Veyon error on E-R300-11: Invalid connection
Comment 3 Jan-Luca Kiok univentionstaff 2024-09-20 12:39:35 CEST
As stated in some of the comments in similar issues this error can be addressed by decoupling exam mode and computerroom functionality. This was recently implemented and released via Bug #57604, so I am closing this issue as a duplicate.

Feel free to re-open or clone this bug if the error still persists.

*** This bug has been marked as a duplicate of bug 57604 ***